RAW measurement

Measuring residual moisture with maximum reliability. 
Fast. Precise. Non-destructive.

The innovative RAW measurement method heralds a new generation of residual moisture measurement. By using electromagnetic waves, 
the moisture in the screed is measured quickly, precisely, reproducibly and in a completely non-destructive manner.

Unlike conventional methods, no drilling, material sampling or other interventions in the screed structure are required. 
The floor remains completely undamaged – from the first to the last measurement.

Thanks to the extremely short measurement time of just a few seconds per measurement point, significantly more measurements can be carried out within a very short time. 
This enables a comprehensive inspection of the entire screed. Critical areas can be specifically 
identified, and additional check measurements can be carried out easily at any time.

This large number of measurement points ensures a significantly higher degree of reliability when assessing the moisture content. 
Instead of a selective analysis, a comprehensive picture of the actual moisture distribution within the screed is obtained.

 

Your benefits

  • Non-destructive
    No sampling required, no damage to the screed
  • Quick and straightforward
    Precise measurement results in just a few seconds
  • Reproducible
    High measurement reliability thanks to modern sensor technology

  • Easy to use
    No time-consuming preparation required; ready for immediate use
  • Versatile
    Can be used even when underfloor heating is in operation
  • Reduces errors
    Fewer manual steps – fewer sources of error

Maximum reliability through the combination of two innovative testing methods

Double-checked. Double-assured.
By combining fluorescence measurement with RAW measurement, PCT Chemie offers a reliable testing concept.


Fluorescence measurement
reliably confirms the correct dosage of RETANOLS® in the installed screed.


RAW measurement
then enables a rapid, non-destructive and comprehensive check of residual moisture – without damaging the screed.

The key advantage of RAW measurement
Thanks to the short measurement time of just a few seconds, numerous measurements can be carried out at many different points. This provides a comprehensive picture of the actual moisture distribution throughout the entire screed. The measurement is carried out independently of any existing underfloor heating. Precise and reliable measurements are possible at any time, even when the underfloor heating is already in operation.

The result is maximum certainty
The dosage is verified, the residual moisture is checked across the entire surface and potential uncertainties are reduced to a minimum. The combination of both measurement methods offers maximum certainty.
 

 

THE PCT SAFETY PLUS

+ Verification of correct dosage via fluorescence measurement

+ Comprehensive residual moisture monitoring via RAW measurement

+ Without damaging the screed

+ More measurement points in less time

+ Maximum reliability thanks to reproducible measurement results
 

 


TWO INDEPENDENT TEST PROCEDURES. 
ONE AIM: MAXIMUM SAFETY FOR THE ROAD STRUCTURE. 
 

What used to be checked on a selective basis can now be inspected almost across the board. The combination of fluorescence measurement and RAW technology takes quality assurance to a new level – fast, non-destructive and with a level of certainty that visibly inspires confidence.

 

OUR SAFETY COMMITMENT TO YOU

The significantly shorter measurement time offered by the RAW method enabled over 500 % more measurements to be taken in the same period than in the previous year, when residual moisture was still being tested using the CM method. The combination of fluorescence measurement and RAW technology takes quality assurance to a new level – fast, non-destructive and with a level of certainty that visibly inspires confidence.


 
A modern benchmark for an industry that expects more, because:

 Quality is non-negotiable

ARE YOU CURIOUS?

Alexandra wagner

Head of Research & Development

+49  7159 4062273